BJGYY - VAPEX LATEX FLAT HOUSE PASTEL BASE 31675
- MSDS: BJGYY
- Manufacturer: PRATT AND LAMBERT INC
- Product Name: VAPEX LATEX FLAT HOUSE PASTEL BASE 31675
- National Stock Number: 8010-00F013043
Product Identification
Product ID:VAPEX LATEX FLAT HOUSE PASTEL BASE 31675
MSDS Date:02/11/1986
FSC:8010
NIIN:00F013043
MSDS Number: BJGYY
Responsible Party
Emergency Phone: (716) 873-6000
Info Phone: (716) 873-6000
Preparer: MEL ERDMAN
Cage: FO127
Contractor
Telephone: 216-566-2902
Cage: 61196
Ingredients
TITANIUM DIOXIDE
CAS: 13463-67-7
RTECS: XR2275000
Fraction By Weight: 15.000%
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST; 9293
SILICA AMORPHOUS HYDRATED, SILICEOUS EARTH, FUMED
CAS: 112945-52-5
RTECS: VV7310000
Fraction By Weight: 20.000%
OSHA PEL 80 MG/CUM (%SIO2+2)
ACGIH TLV: 0.2 MG/CUM RESP/DUST
4.5
RTECS: 9999999VO
ETHYLENE GLYCOL (SARA III)
CAS: 107-21-1
RTECS: KW2975000
Fraction By Weight: 5.000%
OSHA PEL C 50 PPM
ACGIH TLV: C 50 PPM,VAPOR; 9192
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
Hazards
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INGESTION: ABDOMINAL DISCOMFORT OR
PAIN, DIZZINESS, MALAISE, LUMBAR PAIN, OLIGURIA, UREMIA, CNS
DEPRESSION, SEVERE KIDNEY DAMAGE/FATAL, METABOLIC ACIDOSIS.
HEMODIALYSIS MAY BE REQUIRED. PULMONARY EDEM A W/HYPOXEMIA HAS BEEN
DESCRIBED IN A NUMBER OF PATIENTS FOLLOWING POISONING W/ETHYLENE
GLYCOL.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:INHALATION: REPEATED EXPOSURE TO CRYSTALLINE
SILICA MAY CAUSE PNEUMOCONIOSIS, A PROGRESSIVELY DISABLING LUNG
DISEASE. THE NORMAL CLEARANCE MECHANISM OF THE LUNGS MAY HAVE BEEN
OVERWHELMED AT THE 250 M G/CUM EXPOSURE LEVEL, & THIS MAY HAVE
CONTRIBUTED TO THE OCCURRENCE OF CARCINOGENICITY.
First Aid
First Aid:INGESTION: INDUCE VOMITING BY GIVING 2 GLASSES OF WATER &
STICKING FINGER DOWN THROAT. CONSULT PHYSICIAN. NEVER GIVE ANYTHING
BY MOUTH TO AN UNCONSCIOUS PERSON. INHALATION: REMOVE TO FRESH AIR.
EYES: FLUSH W/WATER UNTIL RELIEVED. CONSULT PHYSICIAN.
Fire Fighting
Flash Point Method:SCC
Flash Point:>200F
Accidental Release
Spill Release Procedures:CONFINE IN SMALL AREA; USE ABSORBENT TO CLEAN
UP. PLACE IN CONTAINER FOR DISPOSAL.
Handling
Handling and Storage Precautions:PROTECT FROM FREEZING OR EXTREMELY
HIGH TEMPERATURES. DON'T TAKE INTERNALLY. CLOSE CONTAINER AFTER
EACH USE. KEEP AWAY FROM CHILDREN.
Exposure Controls
Respiratory Protection:NOT NEEDED
Ventilation:NATURAL VENTILATION SHOULD BE ADEQUATE UNDER NORMAL
CONDITIONS
Protective Gloves:NOT NEEDED
Eye Protection:FACE SHIELD, GOGGLES
Other Protective Equipment:NOT NEEDED
Supplemental Safety and Health
WT/GAL: 11.3
Chemical Properties
Boiling Pt:B.P. Text:28-430F
Vapor Density:>AIR
Evaporation Rate & Reference:SLOWER THAN ETHER
Percent Volatiles by Volume:61%
Stability
Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:FREEZING OR EXTREMELY HIGH TEMPERATURES
Hazardous Decomposition Products:SMOKE, CO, CO2
Disposal
Waste Disposal Methods:DISPOSE IN ACCORDANCE W/FEDERAL, STATE & LOCAL
LAWS. AS PRODUCED, THIS PRODUCT ISN'T A WASTE. IF DISCARDED AS IS,
IT ISN'T CLASSIFIED A HAZARDOUS WASTE UNDER RCRA. COMBUSTIBLE
LIQUID.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.